ASTM F2182 PDF

ASTM F – 11a Standard Test Method for Measurement of Radio Frequency Induced Heating On or Near Passive Implants During Magnetic Resonance. ASTM Fa. Standard Test Method for Measurement of Radio Frequency Induced Heating On or Near Passive Implants During Magnetic. ◇ASTM Fa for Measurement of. Measurement of Radio Frequency Induced. Heating Near Passive Implants During MRI. ◇ASTM.

Author: Bajin JoJok
Country: Saint Kitts and Nevis
Language: English (Spanish)
Genre: History
Published (Last): 15 July 2009
Pages: 432
PDF File Size: 5.68 Mb
ePub File Size: 5.36 Mb
ISBN: 917-2-71886-522-3
Downloads: 32319
Price: Free* [*Free Regsitration Required]
Uploader: Fenrijinn

While the focus in this test method is on 1.

ASTM F2182 – 11a

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. While the focus in this test method is on 1. No other units of measurement are included in this standard. For other implantation conditions for example, external fixation devices, percutaneous needles, catheters or tethered devices such as ablation probesmodifications of this test method are necessary.

Work Item s – proposed revisions of this standard.

Historical Version s – view previous versions of standard. It v2182 the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Other safety issues that should be addressed include magnetically induced displacement force and torque.

  CARROLL POKE RUNYON PDF

Link to Active This link will always route to the current Active version of the standard. D2182 combination of the test results and the computational model results may then be used to help assess the safety of a patient with the implant during an MR scan.

This test method describes a test procedure for evaluating the RF-induced temperature rise associated with an MR procedure involving a specific frequency of RF irradiation of an implant. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

For other implantation conditions for example, external fixation devices, percutaneous needles, catheters or tethered devices such as ablation probesmodifications of this test method are necessary. Referenced Documents purchase separately The documents listed below are f2128 within the subject standard but are not provided as part of the standard. Because of possible additional heating, particularly when implant dimensions approaches or exceeds one quarter of the wavelength of the RF field inside the phantom, conclusions from measurements made at one static magnetic field strength do not apply to other field strengths and frequencies.

  DND 2227 PDF

These two measurements estimate the local SAR and the local additional temperature rise with the implant. The results may be used as an input to a computational model for estimating temperature rise due f21822 the presence of that implant in a patient. Work Item s – proposed revisions of this standard. Active view current version of standard.

ASTM International – Standard References for ASTM F – 11a

The heating measurements are made twice, once with the implant and then repeated at the same location without the implant. The RF coil is assumed to have quadrature excitation. The RF coil is assumed to have quadrature excitation.

Link to Active This link will always route to the current Active version of the standard. Other safety issues that should be addressed include magnetically induced displacement force and torque, as well as proper device function while in various configurations in the MR environment.

No other units of measurement are included in this standard.